Surgical repair of the rotator Cuff Must have good resistance and should restore the tendon footprint. To attain this goal, a stitch with a strong biomechanical profile that avoids tissue strangulation should be used. We describe an arthroscopic suture technique undertaken to repair rotator cuff tears with a single triple-loaded suture anchor. The technique consists of a combination of a horizontal mattress and 2 vertical. simple sutures that are positioned medial to the mattress suture. The suture anchor used is the 5-mm self-tapping ThRevo (Linvatec). This anchor is loaded with 3 sutures: 2 No. 2 nonabsorbable braided polyester sutures of different colors and a central high-strength No. 2 polvethylene Suture. The shape of the anchor eyelet permits all 3 sutures to glide freely. A modified Mason-Allen technique (Alex. stitch) that combines a horizontal side-to-side suture and 2 simples sutures as vertical loops is used. With use of the Spectrum suture passing device and shuttle relay system (Linvatec). both limbs of the centrally located polyethylene suture are passed through the cuff from bottom to top. approximately 1 cm from the tendon edge. This suture is not immediately tied. Next, with use of the same system, the other 2 sutures are placed medially and over the previous horizontal suture. Simple sutures are placed at an approximately 30 degrees angle from the center of the anchor; I is placed anterior and the other posterior. The sutures are tied through the lateral portal. The mattress horizontal central stitch is always tied first, followed by the 2 vertical sutures. The horizontal mattress suture serves as a "rip stop stitch" and theoretically reduces the possibility of cutting out of the simple sutures.

Arthroscopic rotator cuff repair using a triple-loaded suture anchor and a modified Mason-Allen technique (Alex stitch)

Garofalo R;
2007-01-01

Abstract

Surgical repair of the rotator Cuff Must have good resistance and should restore the tendon footprint. To attain this goal, a stitch with a strong biomechanical profile that avoids tissue strangulation should be used. We describe an arthroscopic suture technique undertaken to repair rotator cuff tears with a single triple-loaded suture anchor. The technique consists of a combination of a horizontal mattress and 2 vertical. simple sutures that are positioned medial to the mattress suture. The suture anchor used is the 5-mm self-tapping ThRevo (Linvatec). This anchor is loaded with 3 sutures: 2 No. 2 nonabsorbable braided polyester sutures of different colors and a central high-strength No. 2 polvethylene Suture. The shape of the anchor eyelet permits all 3 sutures to glide freely. A modified Mason-Allen technique (Alex. stitch) that combines a horizontal side-to-side suture and 2 simples sutures as vertical loops is used. With use of the Spectrum suture passing device and shuttle relay system (Linvatec). both limbs of the centrally located polyethylene suture are passed through the cuff from bottom to top. approximately 1 cm from the tendon edge. This suture is not immediately tied. Next, with use of the same system, the other 2 sutures are placed medially and over the previous horizontal suture. Simple sutures are placed at an approximately 30 degrees angle from the center of the anchor; I is placed anterior and the other posterior. The sutures are tied through the lateral portal. The mattress horizontal central stitch is always tied first, followed by the 2 vertical sutures. The horizontal mattress suture serves as a "rip stop stitch" and theoretically reduces the possibility of cutting out of the simple sutures.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12572/19037
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact