Purpose: Thorough this experimental study, the physic features of a modified 23-gauge vitrectomy probe were evaluated in vitro. Methods: A modified vitrectomy probe to increase vitreous outflow rate with a smalldiameter probe, that also minimized tractional forces on the retina, was created and tested. The “new” probe was created by drilling an opening into the inner duct of a traditional 23- gauge probe with electrochemical or electrodischarge micromachining. Both vitreous outflow and tractional forces on the retina were examined using experimental models of vitreous surgery. Results: The additional opening allowed the modified probe to have a cutting rate of 5,000 cuts per minute, while sustaining an outflow approximately 45% higher than in conventional 23-gauge probes. The modified probe performed two cutting actions per cycle, not one, as in standard probes. Because tractional force is influenced by cutting rate, retinal forces were 2.2 times lower than those observed with traditional cutters. Conclusion: The modified probe could be useful in vitreoretinal surgery. It allows for faster vitreous removal while minimizing tractional forces on the retina.

Effects of a modified vitrectomy probe in small-gauge vitrectomy

Savastano, Alfonso;
2017-01-01

Abstract

Purpose: Thorough this experimental study, the physic features of a modified 23-gauge vitrectomy probe were evaluated in vitro. Methods: A modified vitrectomy probe to increase vitreous outflow rate with a smalldiameter probe, that also minimized tractional forces on the retina, was created and tested. The “new” probe was created by drilling an opening into the inner duct of a traditional 23- gauge probe with electrochemical or electrodischarge micromachining. Both vitreous outflow and tractional forces on the retina were examined using experimental models of vitreous surgery. Results: The additional opening allowed the modified probe to have a cutting rate of 5,000 cuts per minute, while sustaining an outflow approximately 45% higher than in conventional 23-gauge probes. The modified probe performed two cutting actions per cycle, not one, as in standard probes. Because tractional force is influenced by cutting rate, retinal forces were 2.2 times lower than those observed with traditional cutters. Conclusion: The modified probe could be useful in vitreoretinal surgery. It allows for faster vitreous removal while minimizing tractional forces on the retina.
2017
flow rate
holed vitrectomy probe
modified vitrectomy probe
surgical cutter
tractional force
vitrectomy probe
vitreoretinal surgery
Ophthalmology
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12572/20533
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact