Purpose: To evaluate three months follow-up of SING IMT implant in patients affected by late-stage AMD. Design: Prospective cohort study. Subjects: In a total of 80 eyes of 40 patients who underwent the enrollment tests, 11 patients' eyes affected by late-stage AMD matched the inclusion criteria and underwent SING IMT implant from February to June 2022. Methods: Before surgery, each patient underwent the enrollment examination to verify inclusion and exclusion criteria. Main outcome measures: BCVA for distance and for near, IOP, ACD and ECD were evaluated at 1 and 3 months follow up. Also quality of life in doing the activities of daily life was evaluated. Results: BCVA for distance and for near improved from baseline to 3 months follow up (23.91 ± 9.418 ETDRS letters and 59.09 ± 11.58 ETDRS letters respectively (p < 0.001). An endothelial cell loss was shown (p < 0.001), with a rate of cell density reduction around 8.3% (baseline vs 3 months). Conclusions: SING IMT could be a valid surgical device to improve patients' sight and quality of life which have been deteriorated by late-stage macular degeneration. Further studies with more patients and longer follow up are needed to confirm our results.
Smaller-Incision new-generation implantable miniature telescope: Three-months follow-up study
Alfonso Savastano;
2024-01-01
Abstract
Purpose: To evaluate three months follow-up of SING IMT implant in patients affected by late-stage AMD. Design: Prospective cohort study. Subjects: In a total of 80 eyes of 40 patients who underwent the enrollment tests, 11 patients' eyes affected by late-stage AMD matched the inclusion criteria and underwent SING IMT implant from February to June 2022. Methods: Before surgery, each patient underwent the enrollment examination to verify inclusion and exclusion criteria. Main outcome measures: BCVA for distance and for near, IOP, ACD and ECD were evaluated at 1 and 3 months follow up. Also quality of life in doing the activities of daily life was evaluated. Results: BCVA for distance and for near improved from baseline to 3 months follow up (23.91 ± 9.418 ETDRS letters and 59.09 ± 11.58 ETDRS letters respectively (p < 0.001). An endothelial cell loss was shown (p < 0.001), with a rate of cell density reduction around 8.3% (baseline vs 3 months). Conclusions: SING IMT could be a valid surgical device to improve patients' sight and quality of life which have been deteriorated by late-stage macular degeneration. Further studies with more patients and longer follow up are needed to confirm our results.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
