AimsPocket hematoma is a common complication of cardiac implantable electronic device (CIED) procedures. the aim of the study was to research the clinical factors associated with pocket hematoma formation after CIED implantation or replacement and to identify the best perioperative antithrombotic management.MethodsWe retrospectively analyzed 500 consecutive patients who underwent to CIED implantation or replacement at our center from November 2014.ResultsAmong our population, 206 patients (41.2%) were on anticoagulant therapy at the time of the intervention: 68 (13.6%) on ongoing Warfarin; 111 (22.2%) on low-molecular-weight heparin (LMWH); and 27 (5.4%) on ongoing direct oral anticoagulants. Antiplatelet therapy was present in 262 (52.4%) patients: In particular, 50 (10%) were on dual antiplatelet therapy, 64 (12.8%) were on single antiplatelet therapy and anticoagulant therapy, whereas 12 (2.4%) were on anticoagulant with dual antiplatelet therapy.Incidence of pocket hematoma after CIEDs implantation was of 4.6%. Considering the different perioperative anticoagulant strategies, patients on LMWH presented the higher hematoma rate [11/100 patients (11.0%), P < 0.001]. At the multivariate analysis, anticoagulant with dual antiplatelet therapy (P = 0.021, OR 6.3, IC 1.3-30.8), left ventricular ejection fraction (LVEF) less than 30% (P < 0.001, OR 7.4, IC 2.7-20.4), and use of LMWH (P = 0.008, OR 3.8, IC 1.4-10.6) resulted the strongest predictors of pocket hematoma (Hosmer test = 0.899).Considering replacement procedures, incidence of pocket hematoma was of 4.4%. The incidence was higher after ICD/CRT-D replacement. The majority of pocket hematoma occurred in patients with mechanical valve prosthesis (3/4 cases, 75%, P < 0.001).ConclusionThe use of LMWH and a low LVEF expose patients to a higher risk of pocket hematoma after CIED procedures. Anticoagulant with dual antiplatelet therapy and LMWH should be avoided.

Clinical predictors of pocket hematoma after cardiac device implantation and replacement

Iliceto S.;
2020-01-01

Abstract

AimsPocket hematoma is a common complication of cardiac implantable electronic device (CIED) procedures. the aim of the study was to research the clinical factors associated with pocket hematoma formation after CIED implantation or replacement and to identify the best perioperative antithrombotic management.MethodsWe retrospectively analyzed 500 consecutive patients who underwent to CIED implantation or replacement at our center from November 2014.ResultsAmong our population, 206 patients (41.2%) were on anticoagulant therapy at the time of the intervention: 68 (13.6%) on ongoing Warfarin; 111 (22.2%) on low-molecular-weight heparin (LMWH); and 27 (5.4%) on ongoing direct oral anticoagulants. Antiplatelet therapy was present in 262 (52.4%) patients: In particular, 50 (10%) were on dual antiplatelet therapy, 64 (12.8%) were on single antiplatelet therapy and anticoagulant therapy, whereas 12 (2.4%) were on anticoagulant with dual antiplatelet therapy.Incidence of pocket hematoma after CIEDs implantation was of 4.6%. Considering the different perioperative anticoagulant strategies, patients on LMWH presented the higher hematoma rate [11/100 patients (11.0%), P < 0.001]. At the multivariate analysis, anticoagulant with dual antiplatelet therapy (P = 0.021, OR 6.3, IC 1.3-30.8), left ventricular ejection fraction (LVEF) less than 30% (P < 0.001, OR 7.4, IC 2.7-20.4), and use of LMWH (P = 0.008, OR 3.8, IC 1.4-10.6) resulted the strongest predictors of pocket hematoma (Hosmer test = 0.899).Considering replacement procedures, incidence of pocket hematoma was of 4.4%. The incidence was higher after ICD/CRT-D replacement. The majority of pocket hematoma occurred in patients with mechanical valve prosthesis (3/4 cases, 75%, P < 0.001).ConclusionThe use of LMWH and a low LVEF expose patients to a higher risk of pocket hematoma after CIED procedures. Anticoagulant with dual antiplatelet therapy and LMWH should be avoided.
2020
antithrombotic therapy
implantable cardiac devices
pocket hematoma
Aged
Aged
80 and over
Anticoagulants
Cardiac Resynchronization Therapy Devices
Device Removal
Dual Anti-Platelet Therapy
Electric Countershock
Female
Fibrinolytic Agents
Heart Valve Prosthesis
Heart Valve Prosthesis Implantation
Hematoma
Humans
Incidence
Male
Middle Aged
Platelet Aggregation Inhibitors
Retrospective Studies
Risk Assessment
Risk Factors
Stroke Volume
Time Factors
Treatment Outcome
Ventricular Dysfunction
Left
Ventricular Function
Left
Cardiac Resynchronization Therapy
Defibrillators
Implantable
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12572/37058
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact